Power Source Power Consumption Heated Air Deliveryĩ3% ' High:43.000 8TU/hour H.Medium:33,900 BTU/hour LMedium:21.000 BTU/hour Low:l6.200 BTU/hour High:40.000 BTU/hour H.Medium: 31,500 BTU/hour LMedium: 19,500 BTU/hour Low: 15.000 BTU/hour SeparateiNot supplied with heater) High: 0.319 Gallon/hour H.Medium: 0 25 Gallon/hour L.Medium: 0.16 Gallon/hour Low 0.12 Gallon/hour 120 Volts AC 60 Hz. Model Fuel Type Heater Efficiency Heat Rating MONITOR HEATING SYSTEMS Section 1: Description Schematic Monitor 441 Printed Circuit Board Wiring Diagram Monitor 422 Printed Circuit Board Wiring Diagram Resistance Values component Voltage Readings Test Point Voltage Troubleshooting Diagrams (Mechanical) Troubleshooting Diagrams (Electrical) Indication of Failure mode
Section 4: Maintenance 4-1 Introduction 4-2 Periodic Maintenance: 4-3 Inspect Exhaust Air Piping 4-4 Verify Igniter Operation, 4-5 Clean Fuel Constant Level Valve Filter 4-6 Cleaning Fusible Link Valve Intake Fitting on M-422 4-7 Corrective Maintenance: 4-8 Replacement of Fuses 4-9 Fuel Contaminationĥ-1 Introduction 5-2 Measurerment of Fuel Flow rate 5-3 Removal of Water Deposits and Contaminants from Fuel Constant Level Valve and Fuel Lines: 5-4 Cleaning the Bum Chamber 4 Burner Pot: 5-5 Cleaning the Fuel Inlet
MONITOR HEATER OPERATION PANEL COVER MANUAL
MONITOR HEATING SYSTEMS Table of Contentsġ-1 Specifications: 1-2 Special Features: 1-3 Safety Features: t-4 Description 1-5 Spill Tray: 1-6 Heater Cabinet: 1-7 Combustion System: 1-8 Combustion Chamber: 1-9 Burner Pot 1-10 Combustion Ring Assembly: 1-11 Burner Cap: 1-12 Flame Sensor 1-13 Igniter 1-14 Combustion Air System: 1-15 Flue Pipe: 1-16 Combustion Blower: 1-17 Heat Exchanger: 1-18 Air Circulation Fan 1-19 Air Pressure Switch 1-20 Fuel Delivery System 1-21 External Fuel Tank 1-22 Fusible,Link Valve: 1-23 Fuel Constant Level Valve 1-24 Solenoid Pump: 1-25 Electrical System 1-26 Microprocessor 1-27 Temperature Sensor 1-28 Safety Mechanism 1-29 Cloth Covered Exhaust Pipe 1-30 Air Circulation Fan Guard 1-31 Fuse 1-32 Overheat Protector Switches : 1-33 Slide Selector For the Reset Temp.Ģ-1 Introduction 2-2 Physical Placement of Heater 2-3 Drilling Requirements: 2-4 Power Requirements 2-5 Fuel Tank Requirements: 2-6 Temperature Sensor Wiring Requirements 2-7 Building Codes: 2-8 Un-packing 2-9 Heater Installation 2-10 Installing an Extension Kit 2-11 Typical Monitor Lifter Pump Installations 2-12 Uses for the Elbow Adapter Kit 2-13 Fuel Tank Installation 2-14 Heater Installationģ-1 Introduction 3-2 Operating Specifications 3-3 Operating Controls and Indicators 3-4 Pre-operation Check List 3-5 Operation 3-6 Manual Heater Operation: 3-7 Automatic Heater Operation 3-8 Reprogrammmg the Monitor Heater: 3-9 Heat Sensor 3-10 Monitor Shutdown: 3-11 Out of Fuel 3-12 Recovery from a Power Failure 3-13 Recovery from Overheat Condition 3-14 Recovery from Blown Fuse 3-15 Operation Control system reserves the right to make improvements and corrections and to alter specifications of products described herein, at any time without prior notice This data is issued to authorized Monitor Servicing Personnel for guidance in the installation and maintenance of the subject product and is intended for use by authorized Monitor service personnel only.
shall not be disclosed, duplicated, nor otherwise copied in whole or part for any other purpose without express written permission of the Legal Department of Monitor Products. The information contained herein is proprietary to Monitor Products.